The P/PH series is a medium size, lightweight standard link plastic carrier. Featuring a large window cavity relative to its overall dimensions, it is an economical solution to automation and light industrial applications.
Inside Width: 1.25″ to 4″ (32 to 102 mm)
Inner Height: 1.32″ to 1.33″ (34 to 34 mm)
Curve Height: 4″ to 10″ (102 to 254 mm)
For larger sizes, see the NP or KL Series
For similar sizes, see the KS Series (slightly smaller, greater unsupported length)
P Series:
Model – Height – Length – Bracket (fixed) – Bracket (moving)**
Example: P1-5-36.00-#2OUT-#2IN
PH Series: Model – Height – Hinged Bar Location* – Length – Bracket (fixed) – Bracket (moving)**
Example: PH2-4-INNER-40.50-#4IN-#4 IN
⇒ Length is specified in inches, to two decimals. It is the distance between flanges ⇒ (see formula on carrier side view diagram)
*Only on PH Series: Hinged bars are available on inner or outer radius. Hinged bars on inside radius is standard. Please specify when ordering.
**Specify bracket flange: inward (IN) or outward (OUT).
Carrier Cross Sectional View
Model
A (inside width)
C (outer width)
Weight (lb/ft)
P1
1.25
1.72
0.35
PH1*
1.25
1.72
0.35
P2
2.50
2.97
0.41
PH2*
2.50
2.97
0.41
P3
4.00
4.47
0.49
PH3*
4.00
4.47
0.49
*Hinged bars are available on inner or outer radius. Hinged bars on inside radius is standard. Please specify when ordering.
Specifications are listed as inches unless otherwise noted
Carrier Side View
Travel/2 + CL (+ Offset Distance From Center*) = Length Dynatect recommends mounting the stationary end of the carrier at the center of travel, minimizing the required length.
In cases where center mounting is not possible, add the distance offset from center to the carrier length calculation.
Height
R (bend radius)
H (curve height)
K (depot)
CL (curve length)
4
1.25
4.00
3.41
6.69
5
1.75
5.00
4.00
9.00
10
4.25
10.00
6.50
16.50
Specifications are listed as inches unless otherwise noted
Design Specs - Metric
How To Create A Part Number
P Series:
Model – Height – Length – Bracket (fixed) – Bracket (moving)**
Example: P1-5-36.00-#2OUT-#2IN
PH Series: Model – Height – Hinged Bar Location* – Length – Bracket (fixed) – Bracket (moving)**
Example: PH2-4-INNER-40.50-#4IN-#4 IN
⇒ Length is specified in inches, to two decimals. It is the distance between flanges ⇒ (see formula on carrier side view diagram)
*Only on PH Series: Hinged bars are available on inner or outer radius. Hinged bars on inside radius is standard. Please specify when ordering.
**Specify bracket flange: inward (IN) or outward (OUT).
Carrier Cross Sectional View
Model
A (inside width)
C (outer width)
Weight (kg/m)
P1
32
44
0.52
PH1*
32
44
0.52
P2
64
75
0.61
PH2*
64
75
0.61
P3
102
114
0.73
PH3*
102
114
0.73
*Hinged bars are available on inner or outer radius. Hinged bars on inside radius is standard. Please specify when ordering.
Specifications are listed as millimeters unless otherwise stated
Carrier Side Viewinches (mm)
Travel/2 + CL (+ Offset Distance From Center*) = Length Dynatect recommends mounting the stationary end of the carrier at the center of travel, minimizing the required length.
In cases where center mounting is not possible, add the distance offset from center to the carrier length calculation.
Height
R (bend radius)
H (curve height)
K (depot)
CL (curve length)
4
32
102
87
170
5
44
127
102
229
10
108
254
165
419
Specifications are listed as millimeters unless otherwise noted
Mounting Brackets
Specify bracket arrangement and direction of flange. Mounting holes can be inward facing or outward facing.
Example: #1 arrangement and inward facing holes = #1-IN
Example: #4 arrangement and outward facing holes = #4-OUT